Energy-Saving Device For Granulator

 
 
Basic introduction
Model definition
Special Features
Note
 
	The energy-saving device of the pulverizer adopts "a kind of motor energy saving system based on three-phase sampling and fast response.
Energy technology" development. The technology is based on the principle of reducing voltage and energy saving, and according to the load monitoring technology Sense the load size quickly, generate a suitable trigger signal, and dynamically adjust the SCR Through angle, the voltage at the input terminal of the motor is controlled to dynamically track the load change, thereby achieving The motor is highly efficient and energy-saving control under frequent, irregular load changes and large impact loads.system. The actual application of active power energy saving ratio can reach 20-35%.
| 
				Model
			 | 
				Unit
			 | 
				DZS-G-18
			 | 
				DZS-G-22
			 | 
				DZS-G-30
			 | 
				DZS-G-37
			 | 
				DZS-G-45
			 | 
| 
				Motor Power
			 | 
				kW
			 | 
				15/18.5
			 | 
				22
			 | 
				30
			 | 
				37
			 | 
				45
			 | 
| 
				Voltage Range
			 | 
				V
			 | 
				380-460
			 | 
				380-460
			 | 
				380-460
			 | 
				380-460
			 | 
				380-460
			 | 
| 
				Model
			 | 
				Unit
			 | 
				DZS-G-55
			 | 
				DZS-G-75
			 | 
				DZS-G-90
			 | 
				DZS-G-110
			 | 
| 
				Motor Power
			 | 
				kW
			 | 
				55
			 | 
				75
			 | 
				90
			 | 
				110
			 | 
| 
				Voltage Range
			 | 
				V
			 | 
				380-460
			 | 
				380-460
			 | 
				380-460
			 | 
				380-460
			 | 
Note
	Don’t be used in series with frequency converter.
	The power supply frequency should be consistent with the oper-
ating frequency of the device.
	Have any special needs, please contact us.
	We reserve right to change specifications without prior notice.
 
	DZS - G - AA
	DZS:Crusher energy saving system
	G:Applicable models:G Means shredder
	AA:Adapted motor power (kW)
	Great energy saving
	Super dynamic soft start with load
	Adaptive balance three phase voltage and current
	Reduce heat loss and temperature rise, improve operation quality
	Optimize magnetic field and improve electromagnetic conversion efficiency
	Improve motor power factor and efficiency
	Prolong motor service life
	Real time load tracking
	Steady control and high reliability